ADA Compliance Ramp

Photo Apr 08, 12 28 06.jpg

ADA Compliance Concrete Ramp in progress by Prestige Construction Company in Gardena. Slope is 8.33% max and less that 2% at each landing. Handrail is at 34″ from the ramp and width clearance is 48″.

ADA Contractor

Photo Apr 17, 06 43 34 (1)

ADA Compliant Curb ramp done by Prestige Construction Company:

406 Curb Ramps

406.1 General. Curb ramps on accessible routes shall comply with 406, 405.2 through 405.5, and 405.10.

406.2 Counter Slope. Counter slopes of adjoining gutters and road surfaces immediately adjacent to the curb ramp shall not be steeper than 1:20. The adjacent surfaces at transitions at curb ramps to walks, gutters, and streets shall be at the same level.

In cross section, a curb ramp with a maximum slope of 1:12 adjoins a surface at the bottom that has a maximum counter slope of 1:20.
Figure 406.2 Counter Slope of Surfaces Adjacent to Curb Ramps

406.3 Sides of Curb Ramps. Where provided, curb ramp flares shall not be steeper than 1:10.

A curb ramp with triangular flared sides is shown.  The flared sides have a maximum 1:10 slope, measured at the curb face.

Figure 406.3 Sides of Curb Ramps

406.4 Landings. Landings shall be provided at the tops of curb ramps. The landing clear length shall be 36 inches (915 mm) minimum. The landing clear width shall be at least as wide as the curb ramp, excluding flared sides, leading to the landing.

EXCEPTION: In alterations, where there is no landing at the top of curb ramps, curb ramp flares shall be provided and shall not be steeper than 1:12.

A plan view of a curb ramp shows the required top landing which has a length of 36 inches (915 mm) minimum in the direction of the ramp run and is at least as wide as the ramp.

Figure 406.4 Landings at the Top of Curb Ramps

406.5 Location. Curb ramps and the flared sides of curb ramps shall be located so that they do not project into vehicular traffic lanes, parking spaces, or parking access aisles. Curb ramps at marked crossings shall be wholly contained within the markings, excluding any flared sides.

406.6 Diagonal Curb Ramps. Diagonal or corner type curb ramps with returned curbs or other well-defined edges shall have the edges parallel to the direction of pedestrian flow. The bottom of diagonal curb ramps shall have a clear space 48 inches (1220 mm) minimum outside active traffic lanes of the roadway. Diagonal curb ramps provided at marked crossings shall provide the 48 inches (1220 mm) minimum clear space within the markings. Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing.

A plan view of a diagonal curb ramp is shown at a marked crossing.  A space 48 inches (220 mm) minimum, measured in the direction of the ramp run, is provided at the bottom of the ramp outside active traffic lanes and within the boundary of the marked pedestrian crossing.  Sections of curb 24 inches (610 mm) minimum in length are shown beyond the flared sides and within the marked crossing.

Figure 406.6 Diagonal or Corner Type Curb Ramps

406.7 Islands. Raised islands in crossings shall be cut through level with the street or have curb ramps at both sides. Each curb ramp shall have a level area 48 inches (1220 mm) long minimum by 36 inches (915 mm) wide minimum at the top of the curb ramp in the part of the island intersected by the crossings. Each 48 inch (1220 mm) minimum by 36 inch (915 mm) minimum area shall be oriented so that the 48 inch (1220 mm) minimum length is in the direction of the running slope of the curb ramp it serves. The 48 inch (1220 mm) minimum by 36 inch (915 mm) minimum areas and the accessible route shall be permitted to overlap.

Figure (a) is a plan view of a raised pedestrian island with a walkway cut through at the same level as the street crossing.  Figure (b) is a plan view of a raised pedestrian island between two traffic lanes.  Aligned curb ramps with side flares slope down on each side.  The level space between the top of both ramps is 48 inches (1220 mm) long minimum.  The width of both ramp runs is 36 inches (915 mm).

Asphalt Paving Contractor

Asphalt Paving Contractor

striping-4Serving Greater Los Angeles, Asphalt Paving Contractor is your ADA Compliant Asphalt Paving and Concrete work specialist contractor for all your needs for parkings and commercial property.

Learn more at: http://www.asphalt-paving-contractor.com

 

American with Disability Act Directory – Business Listing

logo-aLos Angeles based company Biz Wiz Support is launching a website to promote businesses related to the American Disability Act. Following the success of Biz Wiz’s ADA Compliance website www.ada-compliance.com , an ADA Code title III & IV and small business resource, and visitor requests for ADA Compliant companies in their areas, the need for an ADA Compliance Directory became apparent.

ADA-Compliance.directory
ADA-Compliance.directory

Biz Wiz Support is announcing the launch of www.ADA-compliance.directory , a website that gathers listings of professionals, services and goods related to disability in the U.S. www.ADA.directory will be a comprehensive solution for American companies involved in multiple ADA issues.

After thorough market analysis, Franck Vialy, Founder and Owner of Biz Wiz Support and www.ADA-compliance.com , is creating the first National ADA Directory in the U.S. The demand for an ADA Directory has finally been responded to.

Biz Wiz Support is raising funds on Kickstarter to take ADA.directory website nationwide and provide a valuable, easy to use directory. Let Biz Wiz Support market your company for you. Any Company can pre-order a subscription on Kickstarter and help make this project a success.

With your support, ADA.directory can reach many in need across America. The goal of making ADA.directory a paid subscription is to have the means to maintain the site, online marketing and build a reliable, helpful, easy to navigate online complete resource offering complete solutions to ADA demands. Together we can facilitate to make America more accessible. This ADA.directory site combined with www.ada-compliance.com will help Americans with disability in find companies that will help fix their problem.

This directory will be available on all platforms whether you’re the in office, the home, or on the road with a smart phone.

ALC Construction ADA Access Ramp

ADA Compliance travelALC Construction ADA Compliance Access Ramp.

ALC Construction ADA ramp has 4 landings, one at the bottom, one at the top and 2 intermediate. All landing have 5′ clearance for change of direction and a slope less the 2% in every directions. The slope in between landing is under 8.3% in the direction of travel with a cross slope of les than 2%. A continues handrail was install with P on top and bottom of 12″ min.ALC Construction

ADA Ramp & Handrail

ADA Ramp & Handrail

405.2 Maximum Ramp Slope and Rise for Existing Sites, Buildings, and Facilities

Slope1 Maximum Rise
Steeper than 1:10 but not steeper than 1:8 3 inches (75 mm)
Steeper than 1:12 but not steeper than 1:10 6 inches (150 mm)
1. A slope steeper than 1:8 is prohibited.
ALC Construction ADA Ramp & Handrail
ADA Ramp by ALC Construction

Advisory 405.2 Slope. To accommodate the widest range of users, provide ramps with the least possible running slope and, wherever possible, accompany ramps with stairs for use by those individuals for whom distance presents a greater barrier than steps, e.g., people with heart disease or limited stamina.

405.3 Cross Slope. Cross slope of ramp runs shall not be steeper than 1:48.

Advisory 405.3 Cross Slope. Cross slope is the slope of the surface perpendicular to the direction of travel. Cross slope is measured the same way as slope is measured (i.e., the rise over the run).

405.4 Floor or Ground Surfaces. Floor or ground surfaces of ramp runs shall comply with 302. Changes in level other than the running slope and cross slope are not permitted on ramp runs.

405.5 Clear Width. The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum.

This ramp was build by ALC Construction llc